Fiber Optics

 

Network access using fiber-optic cables provides a highly reliable and high-speed access. This service is mostly used by operators of communication services, cable television, Internet service providers, business centers, companies or institutions which have remote branches. Fiber-optic networks ensure a high information throughput, reliability and security.
 
Public institution “Plačiajuostis internetas” provides the following fiber optic network services:

  • Network access using a single-mode fiber-optic cable
  • Network access using a multi-mode fiber-optic cable

 
The services are provided in accordance to the “point-to-point” principle i.e. the service is provided between the two service points.

According to the 23 of July, 2014, European Union (EU) General Affairs Council decision, since the 1 of January, 2015, Lithuania becomes a member of the eurozone, where the single European currency - the Euro - is used. The official and irrevocable conversion exchange rate between the Euro and Litas is - 3.45280 Litas to 1 Euro.
 
Standard technical parameters of the service:

No.ParameterValue

1.

Definition of service:Fiber-optic cable connection service between the RAIN network ODF panel connections or couplings

2.

ServiceNetwork access using a fiber-optic cable;

3.

Availability of the ServicesNo less than 99,9 %

4.

Fiber-optic cable typeSingle-mode

5.

Fiber-optic cable parametersITU G.652 D

6.

The number of fiber-optic fibers1 / 2 pc.

7.

Access Connections in ODF panelsSingle-mode SC (duplex), 2nd Edition meets the ISO 11801 OS1 standard requirements according to IEC 874-14

8.

The polishing type of fiber-optic connectors

UPC (Ultra Physical Contact)

 

9.

Insertion loss

 

9.1.

In the cable<= 0.4 dB / km (at a wavelength of 1310 nm - 1625 nm);
<= 0.25 dB / km (at a wavelength of 1550 nm)

 

9.2.

Within the ODF panel jointsNo more than 0.5 dB

 

9.3.

In fiber welding points

0.1 dB when measured on two sides

 

10.

Return loss

 

10.1.

Within the ODF panel jointsNot less than 50 dB

 

11.

The time of damage reaction1 h.

12.

Maximum service recovery period10 h.

 

13.

Routine network maintenance durationUp to 6 hours per month

Last updated: 16-10-2023